www.jihlavan.cz
info@jihlavan.cz
 

Section Distributors 

Group (section) distributors are building elements (line HP has 1 – 10 sections, line JR 16 - 6 sections) designated for controlling the direction and flow rate of the working fluid in hydraulic circuits. There exist various control options – manual/mechanical, bowden, hydraulic, pneumatic … and a broad range of internal connections providing for various applications, such as hydraulic circuits of high-lift carts, auxiliary hydraulic lifting and manipulation mechanisms in trucks, tractors, slide loaders, etc. 

 

Group Distributor HP 8

 

Technical data:
Name and symbol Units Value
Nominal clearance                               Js mm 8
Nominal pressure                                     pn MPa 25
Maximum pressure                                    Max MPa 28
Minimum pressure                                     pmin MPa 0,8
Admissible outlet pressure                       ptmax MPa 3
Range of pressure regulation MPa 0.8 to 28
Nominal flow rate                                Qn dm³.min_¹ 30
Maximum flow rate                                Max dm³.min_¹ 45
Minimum flow rate                                 Qmin dm³.min_¹ 2
Work fluid mineral oil
Range of kinematic viscosity mm².s_¹ 10 to 400
Maximum startup viscosity mm².s_¹ 1500
Range of work fluid temperature ºC -30 to 80
Range of ambient temperature ºC -30 to 55
Nominal work fluid filtration       10 25
Control power on slide valve Nm 5
Internal leakage cm³.min_¹ 15
Number of sections 1 - 10

 

Group Distributor JR 16.1

 

 

Technical data:
Name and symbol Units Value
Nominal clearance                               Js mm 16
Nominal pressure                                     pn MPa 20
Maximum pressure                                    Max MPa 22
Minimum pressure                                     pmin MPa 0.8
Admissible outlet pressure                      ptmax MPa 1.5
Range of pressure regulation MPa 0.8 to 22
Nominal flow rate                                Qn dm³.min_¹ 90
Maximum flow rate                                Max dm³.min_¹ 130
Minimum flow rate                                 Qmin dm³.min_¹ 2
Work fluid Mineral oils
Range of kinematic viscosity mm².s_¹ 10 to 400
Maximum startup viscosity mm².s_¹ 1,500
Range of work fluid temperature ºC -20 to 80
Range of ambient temperature ºC -20 to 55
Nominal work fluid filtration um 25
Nominal control power moment Nm 10.4
Internal tightness per branch cm³.min_¹ max. 120
 

 

On SPECIAL ORDER basis, our Division of Customized Hydraulics is able to supply also: 

 

Section Distributor HP-12,

All modifications of this component are designated for controlling the direction and safe control of the flow rate in hydraulic systems, type OC (open centre).  The hydraulic section distributor, model OC, can be delivered in modification for serial connection of two or more distributors.  The delivery include a safety valve in each section with optional choking of the work fluid’s flow rate; secondary safety and suction valves; slide valve with flow rate limited to 40 l/min, or 60 l/min for the given work pressure; auto-kickout control, mechanical lever control, draw-bar control, and Bowden hydraulic or pneumatic control; connecting branches: P,T - M27 x 2.0 - G ¾"; A,B - M22 x 1.5 - G½"  

 

 

Technical data:
Name and symbol Units Value
Nominal flow rate      l/min 80
Nominal work pressure    MPa 25
Maximum short-term flow rate l/min 110
Maximum recommended flow rate l/min 90
Minimum flow rate l/min 2
Maximum work pressure MPa  28
Admissible pressure in circuits  MPa 3
Range of pressure regulation MPa 0.8 to 28
Number of sections 1 - 10
Range of kinematic viscosity mm².s_¹ 10 to 400
Maximum startup viscosity mm².s_¹ 1,500
Work fluid mineral oil
Range of work fluid temperature ºC -40 to 80
Range of ambient temperature ºC -40 to 55
Nominal work fluid filtration um 25
Maximum stroke slide valve mm 7.5
Force for maximum slide valve lifting N 250
Internal leakage at 10 MPa cm³.min_¹ < 10